Menu
Your Cart

BD600 Series VFD 2HP 1.5KW 7.0A Single/Three Phase 220V Variable Frequency Drive

BD600 Series VFD 2HP 1.5KW 7.0A Single/Three Phase 220V Variable Frequency Drive
BD600 Series VFD 2HP 1.5KW 7.0A Single/Three Phase 220V Variable Frequency Drive
BD600 Series VFD 2HP 1.5KW 7.0A Single/Three Phase 220V Variable Frequency Drive
BD600 Series VFD 2HP 1.5KW 7.0A Single/Three Phase 220V Variable Frequency Drive
BD600 Series VFD 2HP 1.5KW 7.0A Single/Three Phase 220V Variable Frequency Drive
BD600 Series VFD 2HP 1.5KW 7.0A Single/Three Phase 220V Variable Frequency Drive
BD600 Series VFD 2HP 1.5KW 7.0A Single/Three Phase 220V Variable Frequency Drive
BD600 Series VFD 2HP 1.5KW 7.0A Single/Three Phase 220V Variable Frequency Drive
BD600 Series VFD 2HP 1.5KW 7.0A Single/Three Phase 220V Variable Frequency Drive
BD600 Series VFD 2HP 1.5KW 7.0A Single/Three Phase 220V Variable Frequency Drive
BD600 Series VFD 2HP 1.5KW 7.0A Single/Three Phase 220V Variable Frequency Drive
BD600 Series VFD 2HP 1.5KW 7.0A Single/Three Phase 220V Variable Frequency Drive
BD600 Series VFD 2HP 1.5KW 7.0A Single/Three Phase 220V Variable Frequency Drive
$93.35
5 + $86.82
10 + $81.15
50 + $79.08
100 + $76.17
  • In Stock: 10000
  • Model: BD600-1R5G-2
  • Gross Weight: 2.06kg
  • Certificated: ISO, CE

Available Options

Ships within 24 hours for items in stock!

This VFD with power 2HP(1.5Kw) and single/three phase 220V input voltage. The BD600 series is a high performance Vector Control Variable Frequency Drive(VFD), they are widely used in application of: Metal processing, CNC machine tools, Wire drawing machines, Boiler blower, Induced draft fan, Coal mine underground exhaust fan, Municipal engineering, Counter-cyclone, Centrifugal fan, Circulating water pump, Make-up water pump, Oil field injection water pump, Oil transfer pump, music fountain, Papermaking equipment, Chemical industry, Pharmaceutical industry, Textile industry, etc.


Key Specification

  • Input Voltage: 1-Phase/3-Phase 220VAC±15%
  • Input Frequency: 47~63Hz
  • Input Current: 1-Phase 14.0A, 3-Phase 8.4A
  • Input Power factor: ≥95%
  • Power: 2HP(1.5Kw)
  • Output Current: 7.0A
Operating Environment
Store Temperature -20℃~60℃
Variable Frequency Drive Specification
Input Voltage 1PH 220V / 3PH 220VAC
Input Frequency 47 - 63Hz
Input Current 14A(1PH) / 8.4A(3PH)
Input Power factor ≥95%
Output Power 2HP / 1.5KW
Output Current 7.0A
Control Modes V/F control, non-PG vector control(SVC), PG vector control(FVC)
V/F Control Line, Multiple point, square V/F curve, V/F separation
Operation Command Mode Keypad control, Terminal control, Serial communication control
Frequency Reference Source Digital, analog, pulse frequency, serial communication, multi-step speed, simple PLC and PID The combination of multi-modes and the different modes can be switched
Overload Capacity G type: 150% rated current 60s, 180% rated current 3s; P type: 120% rated current 60s, 150% rated current 3s
Start Torque G type: 0.5Hz/150%(SVC), 0Hz/180%(FVC); P type: 0.5Hz/100%
Speed Adjusting Range 1:100(SVC), 1:1000(FVC)
Speed Control Accuracy ±0.5%(SVC), ±0.02%(FVC)
Carrier Frequency 0.5 to 16.0kHz; automatically adjust carrier frequency according to the load characteristics
Frequency Resolution 0.01Hz(Digital setting); maximum frequency x 0.025%(Anolog setting)
Torque Boost Automatic torque boost; manual torque boost 0.1~30%
Acceleration and Deceleration Mode Line or S-curve, 4 types of acceleration/deceleration time with the range of 0.0~6500.0s
DC Brake Supports starting and stopping DC brake
Jogging Control 0.0Hz~50.00Hz(Jog frequency range); 0~6500.0s(Jog Acc/Dec time)
Simple PLC & Multi-step Speed Operation Built-in PLC or control terminal, 16 steps speed can be set
Built-in PID Built-in PID control to easily realize the closed loop control for the process parameters (such as a pressure, temperature, flow, etc.)
Automatic Voltage Regulation(AVR) Automatically maintain a constant output voltage when the voltage of electricity grid changes
Common DC Bus Multiple inverters can use a common DC bus(Common DC bus function)
Traverse Control Multiple triangular pulse frequency control(Traverse control function)
Fixed Length Control Setting length control
Timing Control 0~6500min(Setting time range)
Input Terminals a. Supports high speed pulse input, b. 1 Analog voltage input 0~10VDC, c. 2 Voltage input 0~10VDC or current input 0~20mA
Output Terminals a. 1 Open collector output, it can be extended to 1 high speed pulse output, b. 2 Relay outputs, c. 2 Analog output: voltage output 0~10VDC or current output 0~20mA
Protection Class IP20
Humidity & Temperature 90%RH or less (no-condensation), -10℃~40℃.Inverter will be derated if ambient temperature exceeds 40℃
Vibration Under 20Hz 9.8m/s(1G), Over 20Hz5.88m/s(0.6G)
Store Environment ≤1000M, indoor(no corrosive gas and liquid)
Cooling Mode Forced air-cooling