Assistance & Formation RSS Feed
0
829
Yes, we have launched PLE and PLM series precistion gearbox which can fit your standard motor.
Please refer to below two links: PLE gearbox and PLM gearbox
..
0
1230
Sorry, you can not use closed loop stepper driver to drive a open loop stepper Motor.
Below are the driver and motor’s relation between closed loop and open loop.
Open Loop Motor
Closed..
0
908
Add a brake on the motor will need two conditions:
1.Motor need a rear shaft with specified shaft(Diameter, Length and D-cut).
2.There are two or three screw holes on motor rear endcap to mount brake...
1
1409
For closed-loop driver, below parameters can be debugged:
Peak Current
Rated current of motor * 1.414
Closed-loop holding current percentage
Normally set 45%(rated current)
Position tracking e..
0
1526
In order to choose the right stepper motor for your application, the following parameters need to be considered:
Holding Torque
Holding torque is the torque when the rated current is applied on its wi..